AS-O (Antistreptolysin O)

Labkit

Immunoturbidimetric method.

Enquiry Now

Share on:

Group A streptococcal (GAS) infections are responsible for 517,000 deaths annually across the world. Once the infection is present within the cells it can cause devastating effects. Streptolysin O (SL-O) is a haemolytic exotoxin that is found in many pathogenic bacteria including GAS. Streptococcus pyogenes produces two distinct haemolysins, termed streptolysins O (oxygen labile) and S (oxygen stable), both of which lyse erythrocytes, polymorphonuclear leucocytes and platelets by forming pores in their cell membrane.

 

 

Streptolysin S is responsible for the β-haemolysis around colonies on blood agar plates. It can also induce the release of lysosomal contents with subsequent cell death after engulfment by phagocytes. In contrast to SL- O, it is not immunogenic due to its small size.

 

SL-O in patient serum causes lysis of red blood cells (RBCs). This toxin poses highly antigenic effects causing the host to produce the antibody anti-streptolysin O (AS-O). The AS-O test measures the neutralization activity of patient serum for SL-O. All results are measured against a serum standardized by the World Health Organization with a value of 20 000 Todd or international units/mL.Clinically, the presence of these antibodies can indicate a recent GAS infection.

Product Features:

Product code 41015:

 

  • Immunoturbidimetric method.
  • For testing neutralizing antibodies AS-O in the human serum and plasma.
  • Ready to use reagents.
  • Longer working reagent stability: 30 days at 2-8°C.
  • No prozone effect up to 3000 iU/mL.
  • Very good correlation with other commercially available reagents.
  • Calibrator included in the pack.
  • The assay is calibrated to the ASO International Calibrator by WHO.
  • AMR: between 20 and 800 iU/mL.
  • Can be programmed on fully automated instruments and on semiautomatic analyzers.
  • 2 levels of controls-optional

 

Product code 41010:

 

  • Immunoturbidimetric method.
  • For testing RF in the human serum and plasma.
  • Ready to use reagents.
  • No prozone effect up to 1500 iU/mL.
  • Very good correlation with other commercially available reagents.
  • Calibrator included in the pack.
  • Multi points calibration (5 levels serial dilution)
  • AMR: between 20 and 940 iU/mL.
  • For usage on semiautomatic analyzers.
  • 2 levels of controls-optional

Product Code

Description

Pack Size

Standard/Control

 

 

41015

R1 = 40 mL, R2 = 10 mL

Calibrator = 1 mL.

41010

R1 = 45 mL, R2 = 2.5 mL

Calibrator = 1 mL.